the projection is strong in this one
the projection is strong in this one
it’s the attitude that one side says both sides have, but we know they (and you) already live in an invented reality anyway.
make sure it’s configured for clean shut downs before your battery runs out, auto power up on restoration, and hope it doesn’t happen. you will eventually have an outage that outlasts your batteries.
I have a large string of batteries from an old telco office, that runs my rack for 14hrs (calculated, I shut everything down around this time) and that did not last for the 2-3 day outage we had after a storm. Without a generator, you will inevitably have an outage, but if you are prepared, then you can mitigate any damage. use NUT if you need to shutdown or power multiple devices from one monitored UPS
if they are chaining them bandwidth will add up, and depending on the switching equipment they could be doing a large ring of some sort. it would be pretty easy to calculate since cameras are a pretty even throughput.
Looks like a air fiber 24 which is only 1.5Gbps throughput, 8-24mbps per camera would mean between 60-200 cameras, which for a state transportation department wouldn’t be unreasonable, especially they are using these for something else, like interconnects between buildings for a metro-lan scenario.
would be a good idea to test the backups on 7, and double check the release notes, they hold just about every caveats. The 7to8 upgrade was not horrible, if you have backups, you could always attempt the upgrade after taking backups, then if successful take new backups, test, then install new drives and restore. depends on how paranoid you feel.
If this was a production system, that is probably the change plan i would follow, but in production I would also be able to migrate VMs. I am not nearly as careful in the home environment.
what about that doesn’t work? just because you don’t know how doesn’t mean not possible.
https://developers.cloudflare.com/dns/manage-dns-records/how-to/managing-dynamic-ip-addresses/
https://github.com/ddclient/ddclient#using-ddclient-with-dhcpcd
https://openvpn.net/community-resources/configuring-openvpn-to-run-automatically-on-system-startup/
maybe a vpn provider that uses openvpn? advanced setup but you can have an openvpn client auto connect on boot and bind the mail and ddclient to the tunnel interface.
cloudflare has good support for ddclient, so when your IP changes updates are automatic.
from your router can you ping the AP behind that switch, while the issue is occurring? All L2 unmanaged switches, no tagging? POE from the switch or an injector? If from the switch maybe put an injector in between?
I work for an ISP in the network engineering dept, I personally have never seen an issue exactly like this before, but we generally do power calculations for switching and wifi, this sounds like a power issue to me.
one of the reasons you see these as separate is because of the amount of modularity you get with grafana, you don’t always use it with prometheus, sometimes with ELK sometimes Influx and Telegraf. If you intend to set it up outside of the “typical” you start to really appreciate one piece doing one thing, and doing it well.
i like it, i have been pretty happy with it, but i was also specifically looking for keeping notes in markdown, so ymmv depending on what you want/need. i run it on a docker server i already had, using compose and it has been very stable
either the provider router/dhcpv6 and delegation or the cpe (your router) is misconfigured. ipv6 support on consumer equipment really is pretty straightforward
i didn’t downvote but 17v on a 12v battery maybe seems a bit high. I’m more used to about 7-14% over (maybe up to 14v on a 12v batt) when charged/floating but i don’t use solar anywhere currently, and i usually work on 48v systems. i normally expect to see about 54v on a fully charged battery string (13.5v per battery x4) with the rectifiers running.
i also second the opinion of running an automotive PSU for this situation.
edit: i looked it up since i was curious, some “12v” solar panels can output between 16-20v, but it’s recommended that you would use a charge controller, especially if you have lead-acid batteries
99% of the time im not in a situation where i am being confronted by cops, but crossing a border or a traffic stop it is nice to know
as soon as it shows up, i have also learned in this thread that clicking the power button 5 times does the same
PSA FOR IPHONE:
if you press volume up, then volume down, then hold the power button until the power slider comes on, then it will disable biometrics until next unlock
that didn’t have any list of states, but my curiosity lead me here https://propertyclub.nyc/article/apartment-air-conditioning-laws#what-states-require-air-conditioning
i was pleasantly surprised to find 24 states that do require it, with some other states that have some loopholes.
i absolutely agree, my point is less that there are or are not health concerns, just that it is currently not a requirement, at least anywhere I have lived. i believe it should be, but I know that the south passing legislation that helps vulnerable people at the expense of those who own property is probably never going to happen. i just felt like it was odd that the article was stating that there is no law in the state, without emphasizing that most states do not either.
I rip ass, threaten fart, get out of my body.